Positioning Service#

The Positioning service is the deployment boundary for live source-pose capabilities. The service shell connects to MQTT, publishes resolver status, and exposes health checks. When PTZ sources are configured, it polls each ONVIF PTZ camera, passes raw PTZSample messages in-process to the PTZ Resolver, and publishes one resolved PoseContext per accepted sample.

Note: The Scene Controller can consume resolved poses when you enable its PTZ mode; see PTZ Pose Consumption. The Tracker does not consume poses yet. With the Controller mode off, publishing poses does not change how detections are tracked.

How It Works#

The service connects to the standard MQTT broker TLS listener on port 1883 and verifies the broker against the SceneScape CA certificate. It uses positioning.auth like other SceneScape services. After it connects, it publishes a retained status message and registers an offline last-will message on:

scenescape/positioning/status/{resolver_id}

The payload contains resolver_id, status (online or offline), and timestamp. For the last-will message, the timestamp is the session start time, not the time the connection was lost.

The service writes only its resolver status topic and the resolved-pose topics of its assigned sources (scenescape/positioning/pose/{source_id}), and subscribes only to camera configuration invalidations for those assigned sources (scenescape/cmd/camera/config/{camera_id}). Source ownership is validated at startup against the shared assignment manifest. The container reports healthy only while it is connected to the broker.

PTZ polling#

One poller thread per configured source calls ONVIF PTZ GetStatus every poll_interval_s (default 0.2 s, 5 Hz), including while the camera is stationary. If a call overruns its tick, missed ticks are skipped; no burst, retry queue, or replay follows. Each reading becomes one generated scenescape.ptz.v1.PTZSample and is passed in-process to the sample sink:

Field

Value

camera_id

Configured source_id (the Manager camera UID)

adapter_instance_id

New UUID each time the service starts a poller; unchanged across device reconnects

sequence

Starts at 1 and increments by one per emitted sample within adapter_instance_id

measured_at

Host wall-clock midpoint of the GetStatus request/response interval

timestamp_uncertainty_ns

Half the measured round trip, rounded up (never 0)

position

Raw pan/tilt (and zoom when reported); the reported space URI and its advertised GetNodes ranges

reported_move_status

Advisory only; from GetStatus MoveStatus, a vendor move event, or UNSPECIFIED (see move_status)

If the device reports a position space that its PTZ node does not advertise, the ranges are NaN so the Resolver can reject the sample. The poller applies no calibration math and never writes to Manager or MQTT. After max_consecutive_failures failed polls (default 5), it reconnects with exponential backoff capped at 30 s.

Move events#

Some cameras publish a vendor “is moving” property event. For example, Axis cameras publish tns1:PTZController/tnsaxis:Move/Channel_1 with the is_moving data item. When move_event is configured, a separate thread holds an ONVIF PullPoint subscription, renews it, and always unsubscribes on shutdown, because devices limit concurrent PullPoints. Each state change is logged as a structured ptz_move_event JSON record containing source_id, is_moving, property_operation, device_utc_time, and received_at. These records are evidence for calibration. If move_status is event, the latest event state also sets reported_move_status. Move events never establish pose validity: the Resolver derives motion from position history.

ONVIF client#

The poller uses a small in-tree SOAP 1.2 client (positioning/src/positioning/onvif/) built on requests and defusedxml, both pinned with hashes in requirements-runtime.txt. It implements only GetSystemDateAndTime, GetCapabilities, GetDeviceInformation, GetProfiles, GetNodes, GetStatus, GetEventProperties, and PullPoint create, pull, renew, and unsubscribe operations. These alternatives were evaluated:

Option

Decision and reason

onvif-zeep 0.2.12 (MIT)

Rejected: last released in 2018 and unmaintained. It needs monkey patches for drifting device clocks and Axis subscription reference parameters.

onvif-zeep-async (MIT)

Not selected: it is maintained, but it is async-only and pulls in zeep, lxml, httpx, and their transitive tree, which must all be hash-pinned. It also loads WSDLs at startup, while the poller needs fewer than ten operations.

dlstreamer.onvif

Rejected: it is not published as a package, and the plan forbids cloning or vendoring source during an image build.

In-tree SOAP (requests, defusedxml) (Apache-2.0, MIT, PSF-2.0)

Selected: two small, actively maintained dependencies that support Python 3.11. Device XML is parsed with DTDs and entities forbidden, and responses are limited to 1 MiB. The client times the actual HTTP exchange for the midpoint timestamp.

Authentication uses WS-Security UsernameToken PasswordDigest. The device clock offset is read with an unauthenticated GetSystemDateAndTime and resynchronized after a NotAuthorized fault, so a drifting camera clock does not block authentication. HTTP Digest is used only if the device sends a 401 challenge. Host HTTP proxy variables are ignored for camera traffic. Service addresses advertised by the device keep their path and port, but the configured camera host is always used, so credentials are never sent to a different host. Plain http sends a digest rather than the password; use https where the camera supports it, and keep cameras on an isolated network.

The design rationale is in the PTZ pose design.

Pose resolution#

The Resolver validates every sample before accepting it: finite position and ranges, position inside the advertised ranges, a position space URI and ranges matching the calibration, timestamp uncertainty within max_timestamp_uncertainty_s, and a strictly increasing sequence. Duplicate, out-of-order, malformed, or unassigned samples produce no PoseContext; consumers see them as sequence gaps. A new adapter_instance_id (poller restart) or a sequence gap resets motion and backlash history. A newer sequence whose timestamp does not increase indicates a backward host-clock step: the Resolver accepts it as invalid_sample and resets timestamp continuity together with motion and backlash history.

Every accepted sample publishes exactly one retained QoS 0 PoseContext on scenescape/positioning/pose/{source_id}. A pose is valid only when all of these hold:

  • The clock is synchronized (see Clock synchronization).

  • The sample is younger than max_pose_age_s; otherwise sample_stale.

  • A Manager calibration is loaded; otherwise calibration_missing.

  • Backlash is known on both axes. After a restart, gap, or calibration change, an axis becomes known only when the camera reports a position within backlash_home_tolerance_deg of its calibrated home; otherwise backlash_unknown.

  • The camera is stationary: no axis moved more than settle_angular_threshold_deg between samples (slewing, reason moving), and the history covers a full settle_interval_s window without motion (settling).

  • The calibration’s reprojection_rms_px does not exceed target_reprojection_rms_px, and the Manager home pose is a rigid transform.

The resolved orientation composes backlash-corrected pan and tilt deltas about the calibrated axes in the calibration’s composition_order. Each axis’s home reference uses the calibrated approach_direction (ONVIF position travel direction) and the curve’s angular direction: the physical angle trails the reported home angle by half the home backlash. Continuing in that direction moves immediately; a reversal consumes the full slack. Translation, intrinsics, and distortion stay those of the home calibration.

Calibration reload#

Calibration comes only from Manager. When Manager publishes scenescape/cmd/camera/config/{camera_id} for an assigned source, the Resolver marks that source reload-pending and publishes invalid poses with calibration_changed. It retains the cached calibration and motion continuity while the read is in flight. An identical calibration reload restores valid pose publication without requiring a return to home; a changed calibration resets motion and backlash history, so a valid pose again requires known backlash and a full settle window. Reloads run on a background worker, not in the MQTT callback. Every calibration_refresh_interval_s the service also rereads all sources, which retries failed reloads and recovers from a missed notification. This refresh follows its own monotonic schedule, so frequent notifications for one source cannot postpone it.

Each invalidation advances a per-source generation. A reload captures the generation before reading from Manager and applies its result only if the generation is still current, so a read that was in flight during an invalidation cannot restore the old calibration; the queued reload fetches the replacement.

Positioning configures a 10-second connection and read-inactivity timeout on its Manager RESTClient; authentication and camera reads both use that timeout. A timeout follows the existing calibration failure handling and permits a later refresh to retry; it is not a total deadline for the complete calibration load. Timeouts and connection failures during camera reads preserve the current calibration state (a source already pending reload stays invalid). Definitive rejections, including a deleted camera, identity mismatch, invalid calibration, or insufficient runtime history capacity, clear the calibration and invalidate the source even during a periodic refresh without a configuration notification. Rejections use the same generation guard as successful reloads, so stale failures cannot clear a newer calibration.

Clock synchronization#

Poses are timestamped with the host clock, so the service checks it against the NTP server given by --ntp (default: the POSITIONING_NTP_SERVER environment variable) at startup and every 30 s, and logs the measured offset. While the absolute offset exceeds max_clock_offset_s, no NTP server is configured, or no successful measurement is younger than 90 s, every source publishes invalid poses with reason invalid_sample; motion history and timestamp continuity are discarded, while sequence ordering still rejects duplicates and replays. A failed or non-finite NTP request also invalidates synchronization immediately, regardless of the age of the previous measurement. The service keeps running and recovers automatically once a successful in-range measurement returns, including after a backward clock correction.

Runtime metrics#

Every 60 s the service emits one structured positioning_metrics JSON record at DEBUG level. Set the Positioning log level to DEBUG to make these records visible; at the default INFO level they are intentionally quiet. Each histogram snapshot contains cumulative bucket counts, observation count, and sum:

Metric

Type

Labels

positioning_pose_age_seconds

Histogram

source_id

positioning_pose_sequence_gaps_total

Counter

source_id

positioning_rejected_samples_total

Counter

source_id, result

positioning_motion_state_seconds

Histogram (time spent)

source_id, motion_state

positioning_calibration_version_info

Info

source_id

positioning_clock_offset_seconds

Gauge

-

Dwell-rejection and projection-drift metrics belong to the Controller and Tracker consumers, which see detections; the Positioning service does not.

Build#

Build the runtime image from the repository root:

make positioning

The image is also built by make build-core and make build-all. Generate the broker account with:

make init-secrets

This creates manager/secrets/positioning.auth, which is also used as the Manager REST API credential.

Configure#

The service reads /app/config/positioning.json:

{
  "resolver_id": "positioning-default"
}

Field

Description

resolver_id

Identifies this service instance in its status topic. Must be a single MQTT topic segment (no /, +, or #).

PTZ sources are optional and come from deployment configuration. The checked-in configuration has none:

{
  "resolver_id": "positioning-default",
  "poll_interval_s": 0.2,
  "max_pose_age_s": 0.5,
  "max_timestamp_uncertainty_s": 0.01,
  "max_clock_offset_s": 0.05,
  "target_reprojection_rms_px": 3.0,
  "sample_ring_buffer_size": 64,
  "calibration_refresh_interval_s": 30.0,
  "sources": {
    "<manager-camera-uid>": {
      "type": "onvif_ptz",
      "host": "<camera-host>",
      "scheme": "https",
      "port": 443,
      "credentials_file": "/run/secrets/onvif/<manager-camera-uid>.json",
      "move_status": "event",
      "move_event": { "topic": "PTZController/Move", "data_item": "is_moving" }
    }
  }
}

Field

Default

Description

poll_interval_s

0.2

Positive poll period for every source

sources.<id>

-

Key is the source_id (Manager camera UID, single topic segment)

type

required

onvif_ptz

host, port

-, 443

Camera ONVIF endpoint; host is a bare hostname or IP

scheme, tls_ca_file

https, -

HTTPS is the default; optionally provide the CA bundle path for a private camera certificate

profile_token

first PTZ

Media profile whose PTZ configuration is polled

credentials_file

required

Mounted secret: {"username": "...", "password": "..."}. Credentials are never accepted inline.

request_timeout_s

1.0

Per-request HTTP timeout

move_status

get_status

Source of advisory reported_move_status: get_status, event (requires move_event), or none

move_event

-

topic (event topic prefix without namespace prefixes) and data_item of a boolean move event; when set, ptz_move_event records are always logged

max_pose_age_s

required with sources

Positive maximum sample age; at least poll_interval_s + max_timestamp_uncertainty_s

max_timestamp_uncertainty_s

required with sources

Finite nonnegative upper bound for poller timestamp uncertainty

max_clock_offset_s

required with sources

Positive bound on the measured NTP offset; larger offsets invalidate all poses

target_reprojection_rms_px

required with sources

Positive calibration-quality limit; larger Manager residuals invalidate poses

sample_ring_buffer_size

64

Must cover the largest settle/backlash history: ceil(max_history_s / poll_interval_s) + 2

calibration_refresh_interval_s

30.0

Positive retry interval for Manager calibration loads

Unknown keys are rejected at startup. Device credentials must never be committed. Keep them in deployment secrets mounted read-only into the container.

Source ownership is recorded separately in deployment/positioning-assignments.json as a source_id to resolver_id mapping. The image contains the empty default at /app/deployment/positioning-assignments.json; mount the deployment manifest over it. At startup, every configured source must be assigned to this resolver_id, and every entry assigned to this resolver_id must be configured; otherwise the service exits. The Scene Controller reads the same manifest; see Source Ownership. Manager remains authoritative for camera-to-scene membership and camera calibration. The service loads each camera’s ptz_calibration, computed pose_matrix, and scene through the read-only Manager API. It subscribes only to configuration invalidations for its assigned sources and retries calibration reads periodically. Failed or incomplete calibration keeps the source invalid; a live pose is never used as a home fallback. Accepted samples publish retained QoS 0 contexts on scenescape/positioning/pose/{source_id}; malformed raw samples produce no context.

The service accepts these command-line options:

Option

Default

--broker

broker.scenescape.intel.com

--brokerauth

/run/secrets/positioning.auth

--cert

none (optional client certificate)

--keyfile

none (optional client private key)

--rootcert

/run/secrets/certs/scenescape-ca.pem

--manager-url

https://web.scenescape.intel.com/api/v1

--manager-auth

defaults to --brokerauth

--ntp

POSITIONING_NTP_SERVER environment variable

--config

/app/config/positioning.json

--assignments

/app/deployment/positioning-assignments.json

Deploy#

On Kubernetes, enable the service with positioning.enabled=true and configure sources, resolver limits, assignments, ONVIF credential Secrets, and camera network allowlists through the positioning.* Helm values. See Deploy Scenescape on Kubernetes for the related Helm values. The chart runs one replica, because only one instance may publish poses for a given camera.

To roll back, disable the Positioning deployment or remove its sources. Without sources the service publishes no poses. With the Controller PTZ mode off (the default), either change leaves tracking unchanged; Tracker does not consume poses yet. To roll back the Controller consumer, turn off its PTZ mode instead; see PTZ Pose Consumption.