Configure Alerts#
This section provides instructions for setting up alerts in Time Series Analytics Microservice.
Publish MQTT Alerts#
Configure MQTT Alerts#
By default, the following MQTT alerts are configured in the
configs/time-series-analytics-microservice/config.json
file (see the alerts section).
Configure MQTT Alert in TICK Script#
The MQTT alert is configured by default in the TICK script. Refer to
configs/time-series-analytics-microservice/tick_scripts/weld_anomaly_detector.tick
for the alert() block details.
Note
Setting QoS to 1 ensures messages are delivered at least once. Alerts are preserved and resent if the MQTT broker reconnects after downtime.
Subscribe to MQTT Alerts#
Follow the steps to subscribe to the published MQTT alerts.
To subscribe to all MQTT topics, execute the following command:
docker exec -ti ia-mqtt-broker mosquitto_sub -h localhost -v -t '#' -p 1883
Subscribing to Time Series Analytics Microservice Alerts#
docker exec -ti ia-mqtt-broker mosquitto_sub -h localhost -v -t alerts/weld_defect_detection -p 1883
Subscribing to DL Streamer Pipeline Server Results#
docker exec -ti ia-mqtt-broker mosquitto_sub -h localhost -v -t vision_weld_defect_classification -p 1883
Subscribing to Fusion Analytics Results#
docker exec -ti ia-mqtt-broker mosquitto_sub -h localhost -v -t fusion/anomaly_detection_results -p 1883